/* Navigation Bar Contents */
English | Español
Y06S-Series
Sankosha Gas Discharge Tubes (GDT) - Surge Arresters
Applications:

  • Cable Telephony Products
  • Modems/Cable Modems
  • Broadband/CATV/Coaxial Protectors
  • xDSL Modems and Peripherals
  • Building Entry/Outside Plant
  • Transient Voltage Surge Suppression
  • Features:

  • High Surge Current Rating
  • Non-Radioactive
  • Small Size
  • RoHS Compliant (100% Lead-Free)
  • ISO 9001 and ISO 14001 Certified
  • Low Capacitance ≤ 1.5pF
  • High Insulation Resistance(2)
  • Proven Performance

  • Part
    Number
    (Model A)
    Part
    Number
    (Model B1)
    DC Breakdown Voltage(1) Impulse Breakdown Voltage DC Holdover Voltage(3) Impulse Life
    (10/1000μs 100A)
    Impulse Discharge Current (8/20μs) AC Discharge Current
    (50Hz)
    100V/s 100V/μs 1kV/μs 1 Time 10 Times(4) 9 Cycles
    1 Time
    1 Second
    Y06S-100A Y06S-100B1 100V ≤ 500V ≤ 700V ≤ 52V 200 Times 3 kA 2.5 kA 20 A 5A, 10 Times
    Y06SZ-230A Y06SZ-230B1 230V ≤ 500V ≤ 700V ≤ 135V 200 Times 10 kA 5 kA 20 A 5A, 10 Times
    Y06SZ-350A Y06SZ-350B1 350V ≤ 600V ≤ 800V ≤ 135V 200 Times 10 kA 5 kA 20 A 5A, 10 Times


    Notes:
    1. DC Breakdown Voltage Ranges are ± 20%
    2. Insulation Resistance for all parts in the Y06S-Series is ≥ 10,000 MΩ measured at:
                DC 50V for the Y06S-100
                DC 100V for the Y06SZ-230 and Y06SZ-350
    3. DC Holdover Voltage measured in accordance with the ITU-T K.12 or the IEEE C62.31-1987 Test Circuit
    4. 5 times each polarity
    5. Capacitance measured at 1 MHz for all part numbers is ≤ 1.5 pF
    Home     Arresters     Grounding     LAN     Coaxial     GlobalSpec     Contact Us     About Sankosha
    Sankosha U.S.A., Inc.,    406 Amapola Avenue, Suite 135,    Torrance, CA 90501,    USA
    Phone Toll Free: (888) 711-2436    Phone: (310) 320-1661    Fax: (310) 618-6869    Email: sales@sankosha-usa.com