/* Navigation Bar Contents */
English | Español
3Y06-Series
Sankosha Gas Discharge Tubes (GDT) - Surge Arresters
Applications:

  • Cable Telephony Products
  • Modems/Cable Modems
  • Broadband/CATV/Coaxial Protectors
  • xDSL Modems and Peripherals
  • Building Entry/Outside Plant
  • Transient Voltage Surge Suppression
  • Features:

  • UL 479B Recognized (File E140906)
  • High Surge Current Rating
  • Non-Radioactive
  • RoHS Compliant (100% Lead-Free)
  • ISO 9001 and ISO 14001 Certified
  • Low Capacitance ≤ 3.0pF(1)
  • Proven Performance

  • Part
    Number
    (Model A)
    Part
    Number
    (Model P1)
    DC Breakdown Voltage
    (L1-E)(L2-E)(1)
    Impulse Breakdown Voltage
    (L1-E)(L2-E)
    Insulation Resistance(2) Capacitance
    (1 MHz)
    DC Holdover Voltage(3) Impulse Life
    (10/1000μs 200A)
    Impulse Discharge Current
    (8/20μs)
    AC Discharge
    Current (L1+L2-E)
    (50Hz)
    100V/s 1kV/μs 10 Times(4) 1 Second
    3Y06-90A 3Y06-90P1 90V ≤ 850V ≥ 10,000 MΩ ≤ 3.0pF ≤ 52V 100 Times 5 kA 5A, 5 Times
    3Y06-230A 3Y06-230P1 230V ≤ 700V ≥ 10,000 MΩ ≤ 3.0pF ≤ 135V 100 Times 10 kA 10A, 5 Times
    3Y06-350A 3Y06-350P1 350V ≤ 750V ≥ 10,000 MΩ ≤ 3.0pF ≤ 150V 100 Times 5 kA 5A, 5 Times


    Notes:
    1. DC Breakdown Voltage Ranges are ± 20%
    2. Insulation Resistance measured at:
                DC 50V for the 3Y06-90
                DC 100V for the 3Y06-230 and 3Y06-350
    3. DC Holdover Voltage measured in accordance with the ITU-T K.12 or the IEEE C62.31-1987 Test Circuit
    4. 5 times each polarity