Applications: |
Features: |
![]() |
Part Number |
DC Breakdown Voltage (L1-E)(L2-E)(1) |
Impulse Breakdown Voltage (L1-E)(L2-E) |
Insulation Resistance(2) | Capacitance (1 MHz) |
DC Holdover Voltage(3) | Impulse Life (10/1000μs 200A) |
Impulse Discharge Current (8/20μs) |
Impulse Discharge Current (10/350μs) |
AC Discharge Current (50Hz) |
100V/s | 1kV/μs | 10 Times(4) | 2 Times | 1 Second | |||||
3YD-90P1 | 90V | ≤ 600V | ≥ 10,000 MΩ | ≤ 3.0pF | ≤ 52V | 100 Times | 5kA x 2 | 2.5kA x 2 | - |
3YD-230P1 | 230V | ≤ 600V | ≥ 10,000 MΩ | ≤ 3.0pF | ≤ 52V | 100 Times | 5kA x 2 | 2.5kA x 2 | 5A x 2 10 Times |
3YD-350P1 | 350V | ≤ 700V | ≥ 10,000 MΩ | ≤ 3.0pF | ≤ 52V | 100 Times | 5kA x 2 | 2.5kA x 2 | 5A x 2 10 Times |
![](graphics/3YD-drawing-p1.jpg)
Notes: |
|