Sankosha Gas Discharge Tubes (GDT) - Surge Arresters
Applications: |
Features: |
Part Number (Model A) |
Part Number (Model B) |
DC Breakdown Voltage | Impulse Breakdown Voltage | DC Holdover Voltage(2) | Impulse Life (10/1000μs 100A) |
Impulse Discharge Current (8/20μs) | AC Discharge Current (50 Hz) |
|||
100V/s | 100V/μs | 1kV/μs | 1 Time | 10 Times(5) | 9 Cycles 1 Time |
1 Second | ||||
Y08JS-90A | Y08JS-90B | 72-108V | ≤ 450V | ≤ 500V | ≤ 52V | 300 Times | 20 kA | 15 kA | 90 A | 20A, 10 Times |
Y08JS-230A | Y08JS-230B | 184-280V | ≤ 600V | ≤ 700V | ≤ 52V | 300 Times | 20 kA | 15 kA | 90 A | 20A, 10 Times |
Y08JS-230AF1(3)(4) | 184-280V | ≤ 600V | ≤ 700V | ≤ 52V | 300 Times | 20 kA | 15 kA | 90 A | 20A, 10 Times | |
Y08JS-350A | Y08JS-350B | 280-420V | ≤ 700V | ≤ 800V | ≤ 52V | 300 Times | 20 kA | 15 kA | 90 A | 20A, 10 Times |
Notes: |
|